Actuator Test Box - For Air-Pro Planters.
The Actuator Test Box (part # AE6690) can be used to troubleshoot the split air actuator and as an
aid in the replacement of it if needed. The planter harness must be electrically connected to the
tractor for the switch box to function. If this is not possible, another 12VDC power supply needs
to be connected to the tower connector of the test box harness (connector with only two wires). Pin
Refer to Figure 2
1. Locate the rotary actuator on the side of the spit air valve.
The spit air valve is always mounted directly next to the fan.
2. Follow the wiring harness that comes out of the rotary
actuator until the 6 pin weatherpack connector is found.
Disconnect the actuator harness from the extension harness
at this location, and connect the two leads of the test box
3. The Actuator Test Box contains a spring centered momentary
switch. Moving the switch to one side or the other will cause
the actuator to rotate either clockwise or counterclockwise.
When the switch is released, it will re-center itself and stop actuator
motion. DO NOT USE THIS TOOL AS A REPLACEMENT
FOR AIR PRESSURE CONTROL DURING PLANTING!
Using the Actuator Test Box for actuator replacement.
1. The rotary actuator is mounted in slots to allow for adjustment to
the assembly. Leave the mounting hardware loose until final
adjustment is made.
2. Connect the test box as described above in step 2.
3. Using the test box, electrically rotate the actuator fully clockwise. (As viewed
looking at the arrow on the face of the actuator.)
Refer to Figure 3
4. Remove the top meter pressure delivery hose closest to the actuator and
visually inspect the location of the split air vane. Adjust the actuator until
the edge of the vane is flush with the bottom of the seed delivery outlet.
Refer to Figure 4
Notes - The rotary actuator contains internal limit switches that are set to hold its rotation within a 60 degree range.
When either switch is tripped, the actuator will stop and can only move back in the opposite direction.
- An internal circuit breaker will cut power to the actuator if it encounters a high amp load. If the actuator will
not move, check for +12VDC in pin A of the 6 pin connector using pin B for the ground. If the voltage is
present but there is no visible LED light in the window of the actuator, unplug it, wait 20 seconds and
reconnect it. This will reset the breaker.
5. Tighten the mounting hardware and use the test box to operate the valve
through its entire range of travel to ensure there is no physical interference.
1
Fig. 4
1
2
1
3
2
Fig. 2
Fig. 3
AE6690
ACTUATOR
TEST BOX
SN: XXXXX
3
2
1
2