Great-plains YP4025A-3215 32-Row 15-Inch Quick Start Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 5
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
Quick Setup Guide for IntelliAg Model YP40 30” Twin Row Air Pro
11001-1542-200909
©2009 DICKEY-john Corporation
Speci cations subject to change without notice.
STEP 12: 5 Revolution Test
Press the Control Setup button .
Press the Channel Setup button .
Press the Next Page button .
Ensure implement is raised before starting 5 Rev Test.
With brakes locked and transmission in PARK position, start tractor engine.
Engage hydraulics and run engine at normal speed until hydraulic uid is at operating
temperature.
Press the 5 Rev button .
Test Ground Speed and Row data must be entered to perform test.
Press and hold remote test button to initiate 5 Rev Test.
1.
2.
3.
4.
5.
6.
7.
8.
9.
4
STEP 14: Summary Screen
The Summary screen provides an overview of setup constants for active control channels.
At the Main Work screen, press the Next Page button .
Press the Summary button
To view speci c control channel con gurations, press the respective control channel box
1-4.
Press inside a yellow highlighted box to open a speci c screen for editing.
Press the Work Screen button to return to the Main Work screen.
1.
2.
3.
4.
5.
Summary
Screen
STEP 11: Clutch Folding Module Operation
The planter section controls turn the left, center, and right clutch controls on and off.
The master switch must be in the ON position to activate any planter section. When a clutch
control is ON, a green light will illuminate.
Marker/Fold Switch should be in the UP (Marker) position during planting. In the DOWN
(Fold) position, the switch controls the fold of the main frame.
The fertilizer pump switch is turned ON when in the UP position. Press the switch in the
DOWN position to turn OFF.
Lift/Hitch switch should be in the UP (Lift) position during normal operation. In the hitch posi-
tion, the switch should be in the DOWN (Hitch) position to unlock and extend the telescoping
tongue in preparation of folding the implement for transport.
Lift/Hitch switch MUST be in the hitch position and hydraulic circuit in FLOAT when trans-
porting planter equipped with hydraulic-operated tongue hitch. NOTE: Lift/Hitch switch has
no function if planter has standard 3-point hitch operated tongue hitch.
1.
2.
3.
4.
5.
6.
MASTER
Left Center Right Marker Fert. Pump Lift
MASTERMASTER
CLUTCH
Fold Hitch
Master
CFM Switch
Marker
or
Fold
Fertilizer
Pump
On/Off
Lift
or
Hitch
TABLE F:
Accessory
Setup
Default Value
or Value to
Enter
Instructions/De nitions
Hopper Setup
# of Hoppers 1 (base unit)
1 more (optional)
# of hopper sensors connected to each module
(4 sensors maximum). # of hopper data items for
each listed module and the Hopp #’s value will auto-
matically populate if Auto Con g is used to con gure
installed sensors.
Logic Level Active Lo Sets the active state to low signifying that an alarm
is generated if the sensor’s output is in a low state.
Use this setting if the connected sensor outputs a
low condition when empty similar to the DICKEY-john
hopper sensor.
Alarm Delay 5 sec Controls the delay time between the detection of a
high/low hopper alarm condition and the generation of
the resulting alarm. The value is entered in seconds.
Channel Assigns hopper sensor to channel.
RPM Setup
High Alarm
(fan speed)
3000 rpm Sets the RPM value at which a high RPM warning
error is generated.
Low Alarm
(fan speed)
1800 rpm Sets the RPM value at which a low RPM warning error
is generated.
High Alarm Delay 10 sec Establishes the delay between the detection of a high
RPM alarm condition and the resulting alarm display.
The value is entered in seconds.
Low Alarm Delay 10 sec Establishes the delay between the detection of a low
RPM alarm condition and the resulting alarm display.
The value is entered in seconds.
RPM Constant 3 pulses/rev Number of pulses per sensor revolution.
RPM Filter 0 Filters the signal out of the RPM sensor.
Disable Control
on Low Alarm
Disabled Allows for disabling of all control channels if the RPM
value of the selected sensor falls below the low alarm
level setting.
STEP 9: Accessory Sensor Setup
Hopper Assignment
At the Main Work screen, press the Next Page button
.
Press the Module Con guration button to display the Module Con guration screen.
At the Module Con guration screen, press the Hopper Assign button .
Press Hopper Set button .
Enter desired values using Table F as reference.
RPM Assignment
At the Module Con guration screen, press the Acc Assign button .
Press the RPM Setup button .
Enter # of RPMs, if required. NOTE: There must be at least 1 RPM sensor con gured
before the RPM Setup button appears on the screen.
Enter desired values using Table F as reference.
1.
2.
3.
4.
5.
1.
2.
3.
6.
STEP 10: Clutch Folding Module (CFM) Setup
The CFM is installed in the cab to control row clutches, marker, fold, fertilizer on/off, lift and
hitch.
At the Main Work screen, press the Clutch CFG button to access the Clutch Con guration
screen and verify that the correct # of clutches are con gured for the system.
The Clutch CFG button only appears as a top level button when a planter output
module and clutch folding module are installed.
1.
2.
OUTPUT
1-10
# OF
ROWS
ROW
#’s
11-22
23-32
LEFT
CENTER
RIGHT
10
12
10
# of Clutches
3
Vue de la page 3
1 2 3 4 5

Commentaires sur ces manuels

Pas de commentaire