Quick Setup Guide for IntelliAg Model YP1625 70 cm
11001-1597-201108
©2011 DICKEY-john Corporation
Speci cations subject to change without notice.
STEP 7: Row Monitor Setup
At the Main Work screen, press the Row Monitor button .
Enter desired values using Table D as reference.
Press the Work Screen button
to return to the Main Work screen.
1.
2.
3.
TABLE D:
Row Monitor
Setup
Default Value/
Value to Enter Instructions/De nitions
Material Name See Instructions Material Name only appears on the Row Monitor Setup screen when all
control channels are disabled and material is set for Monitor Only. This is only
used for ground drive/nonhydraulic applications to monitor population with
high and low alarms. A material must be con gured and selected to activate
alarms.
High Alarm Delay 5 Desired number of seconds that high population can be above high alarm
point before alarm will sound.
Low Alarm Delay 5 Desired number of seconds that low population can be below low alarm point
before alarm will sound.
Population Adjust 100 Enter a % to allow for seed sensor population inaccuracies to achieve the
desired population display. 100% represents true calculation.
Population Filter 50 Set lter value to stabilize the monitored population display. Number can be
set to 0% for no ltering and 99% for high level ltering.
Row Fail Rate 2/1 (2 seeds
every 1 second)
Set to desired number of seeds per second to trigger seed sensor failure
alarm.
TABLE E:
Speed Set Default Value/
Value to Enter Instructions/De nitions
Source Digital Frequency Select CAN Ground if radar is connected to ISO tractor cab harness. Select
Digital Frequency if radar or hall-effect is connected to WSMT actuator har-
ness.
Gspd Constant 2546 Input based on pulse count produced by the ground speed sensor over 400’
distance. See Operator’s manual for calibration instructions.
Shutoff Speed 0.5 kph Set desired minimum ground speed allowed before the system shuts off.
Minimum
Override
2.0 kph Set to operate when actual ground speed falls below the designated value.
Control will operate at this speed until actual ground speed rises above mini-
mum override speed or actual speed drops below shutoff.
Master Sw
Timeout
10 Set to desired number of seconds system shuts off if the master switch is
turned on and there is no ground speed. Toggle master switch to restart the
system and turn off alarm.
Gspd Fail Alarm
Delay
5 Set to desired number of seconds alarm sounds after the ground speed is zero
and seed ow continues. (Monitor only)
Precharge
Ground Speed
0 Set to the desired speed the system will use when a precharge time has been
enabled for a control channel. Refer to Table C1: Planter Control Setup for
Precharge Time. This setting will only display when a Precharge Time has
been entered.
Implement Lift Enabled Implement lift switch, when enabled, displays an implement lift indicator on
the Main Work screen indicating implement lift position as up or down. Control
channels can be turned on and off without using the master switch.
STEP 8: Speed Set Calibration Setup
At the Main Work screen, press the Speed Set button .
Enter desired values using Table E as reference.
Press the Work Screen button when ground speed calibration
con gurations are complete to return to the Main Work screen.
1.
2.
3.
TABLE F:
Accessory
Setup
Default Value /
Value to Enter Instructions/De nitions
Hopper Setup
# of Hoppers 1 (base unit)
1 more (optional)
# of hopper sensors connected to each module (4 sensors maximum). # of
hopper data items for each listed module and the Hopp #’s value will automati-
cally populate if Auto Con g is used to con gure installed sensors.
Logic Level Active Lo Sets the active state to low signifying that an alarm is generated if the sensor’s
output is in a low state. Use this setting if the connected sensor outputs a low
condition when empty similar to the DICKEY-john hopper sensor.
Alarm Delay 5 sec Controls the delay time between the detection of a high/low hopper alarm
condition and the generation of the resulting alarm. The value is entered in
seconds.
Channel Assigns hopper sensor to channel.
RPM Setup
High Alarm
(fan speed)
4200 rpm Sets the RPM value at which a high RPM warning error is generated.
Low Alarm
(fan speed)
2900 rpm Sets the RPM value at which a low RPM warning error is generated.
High Alarm Delay 10 sec Establishes the delay between the detection of a high RPM alarm condition
and the resulting alarm display. The value is entered in seconds.
Low Alarm Delay 10 sec Establishes the delay between the detection of a low RPM alarm condition
and the resulting alarm display. The value is entered in seconds.
RPM Constant 3 pulses/rev Number of pulses per sensor revolution.
RPM Filter 0 Filters the signal out of the RPM sensor.
Disable Control
on Low Alarm
Disabled Allows for disabling of all control channels if the RPM value of the selected
sensor falls below the low alarm level setting.
STEP 9: Accessory Sensor Setup
Hopper Assignment
At the Main Work screen, press the Next Page button .
Press the Module Con guration button to display the Module
Con guration screen.
At the Module Con guration screen, press the Hopper Assign button
.
Press Hopper Set button .
Enter desired values using Table F as reference.
RPM Assignment
At the Module Con guration screen, press the Accessory Assignment
button .
Press the RPM Setup button . NOTE: There must be at least 1
RPM sensor con gured before the RPM Setup button appears on the
screen.
Enter desired values using Table F as reference.
1.
2.
3.
4.
5.
6.
7.
8.
3