Great-plains YP3010HDP-4475 10HDP Series 44 Row 7 1-2 Inch Quic Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 5
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
Quick Setup Guide for IntelliAg Model YP30 7.5”
11001-1549-201002
©2010 DICKEY-john Corporation
Speci cations subject to change without notice.
TABLE E:
Speed Set
Default Value
or Value to
Enter Instructions/De nitions
Source Digital Frequency Select CAN Ground if radar is connected to ISO tractor cab harness.
Select Digital Frequency if radar or hall-effect is connected to WSMT
actuator harness.
Gspd Constant 12192 Input based on pulse count produced by the ground speed sensor
over 400’ distance. See Operator’s manual for calibration instructions.
Shutoff Speed 0.5 mph Set desired minimum ground speed allowed before the system shuts
off.
Minimum Over-
ride
2.0 mph Set to operate when actual ground speed falls below the designated
value. Control will operate at this speed until actual ground speed
rises above minimum override speed or actual speed drops below
shutoff.
Master Sw
Timeout
10 Set to desired number of seconds system shuts off if the master
switch is turned on and there is no ground speed. Toggle master
switch to restart the system and turn off alarm.
Gspd Fail Alarm
Delay
5 Set to desired number of seconds alarm sounds after the ground
speed is zero and seed ow continues. (Monitor only)
Precharge
Ground Speed
0 Set to the desired speed the system will use when a precharge time
has been enabled for a control channel. Refer to Table C1: Planter
Control Setup for Precharge Time. This setting will only display when
a Precharge Time has been entered.
Implement Lift Enabled Implement lift switch, when enabled, displays an implement lift indica-
tor on the Main Work screen indicating implement lift position as up
or down. Control channels can be turned on and off without using the
master switch.
3
STEP 8: Speed Set Calibration Setup
At the Main Work screen, press the Speed Set button .
Enter desired values using Table E as reference.
Press the Work Screen button when ground speed calibration con gura-
tions are complete to return to the Main Work screen.
1.
2.
3.
TABLE F:
Accessory
Setup
Default Value
or Value to
Enter
Instructions/De nitions
Hopper Setup
# of Hoppers 1 (base unit)
1 more (optional)
# of hopper sensors connected to each module (4 sensors maximum).
# of hopper data items for each listed module and the Hopp #’s value
will automatically populate if Auto Con g is used to con gure installed
sensors.
Logic Level Active Lo Sets the active state to low signifying that an alarm is generated if the
sensor’s output is in a low state. Use this setting if the connected sen-
sor outputs a low condition when empty similar to the DICKEY-john
hopper sensor.
Alarm Delay 5 sec Controls the delay time between the detection of a high/low hopper
alarm condition and the generation of the resulting alarm. The value is
entered in seconds.
Channel Assigns hopper sensor to channel.
RPM Setup
High Alarm (fan
speed)
4200 rpm Sets the RPM value at which a high RPM warning error is generated.
Low Alarm (fan
speed)
2900 rpm Sets the RPM value at which a low RPM warning error is generated.
High Alarm Delay 10 sec Establishes the delay between the detection of a high RPM alarm
condition and the resulting alarm display. The value is entered in
seconds.
Low Alarm Delay 10 sec Establishes the delay between the detection of a low RPM alarm
condition and the resulting alarm display. The value is entered in
seconds.
RPM Constant 3 pulses/rev Number of pulses per sensor revolution.
RPM Filter 0 Filters the signal out of the RPM sensor.
Disable Control
on Low Alarm
Disabled Allows for disabling of all control channels if the RPM value of the
selected sensor falls below the low alarm level setting.
STEP 9: Accessory Sensor Setup
Hopper Assignment
At the Main Work screen, press the Next Page button .
Press the Module Con guration button to display the Module Con gura-
tion screen.
At the Module Con guration screen, press the Hopper Assign button .
Press Hopper Set button .
Enter desired values using Table F as reference.
RPM Assignment
At the Module Con guration screen, press the Accessory Assignment button
.
Press the RPM Setup button . NOTE: There must be at least 1 RPM sen-
sor con gured before the RPM Setup button appears on the screen.
Enter desired values using Table F as reference.
1.
2.
3.
4.
5.
6.
7.
8.
STEP 10: Clutch Folding Module (CFM) Setup
The CFM is installed in the cab to control row clutches, marker, fold, fertilizer on/off,
lift and hitch.
At the Main Work screen, press the Clutch CFG button to access the Clutch
Con guration screen and verify that the correct # of clutches are con gured for
the system.
The Clutch CFG button only appears as a top level button when a planter
output module and clutch folding module are installed.
1.
2.
OUTPUT
1-15
# OF
ROWS
ROW
#’s
16-29
30-44
LEFT
CENTER
RIGHT
15
14
15
# of Clutches
3
Vue de la page 2
1 2 3 4 5

Commentaires sur ces manuels