Great-plains YP1625A-2420 24 Row 20-Inch Quick Start Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
Quick Setup Guide for IntelliAg Model YP1625 20” Air Pro
11001-1601-201108
©2011 DICKEY-john Corporation
Speci cations subject to change without notice.
TABLE E:
Planter Control
Setup
Default Value/
Value to Enter
Split Air Regulation
Instructions/De nitions
Type Split Air Reg Con gure Control Channel 2 as Split Air Regulation.
Control Mode Auto Control channel feedback based on air pressure sensor.
Drive Type Air Reg 2 Automatically selects Air Reg 2 as drive type.
Input Filter 79 Amount of ltering applied to the control channel feedback frequency.
Pressure Drop 0 Difference in pressure sensor mounting location to the seed disk in inches
of H
2
0.
Pressure Slope 447.2269 The change in pressure sensor voltage to a frequency readable by the
IntelliAg system and measured in inches of H
2
0. Should only be adjusted
by quali ed personnel.
Pressure Offset 800 Takes a zero point reading that provides a frequency when the fan is off.
Press the Zero Pressure button to calculate frequency.
Planter Selection YP16 Select planter selection of YP1625 automatically adjusts to the appropri-
ate calibration settings.
Sensitivity Adjust 0 Increases or decreases the calibration parameters in the ranges of -10 to
+10. Increasing response time makes the system response quicker.
STEP 7B: Planter Control Channel Setup
(Split Air Regulation)
NOTE: Split Air Regulation must be con gured as Control Channel 2
only.
At the Control Setup screen, press the Channel Setup button .
Select Channel 2 and select Split Air Regulation as the Type.
Enter desired values from Table E.
Press the Work Screen button to return to the Main Work screen.
1.
2.
3.
4.
STEP 7A: Material Con guration Setup (Split Air Regulation)
It is recommended that when setting a control channel for split air, the
material name be created as “Air” to eliminate confusion between the
actual material and the control used.
At the Main Menu screen, press the Control Setup button .
Press Material button 16.
Enter desired values from Table D.
Press the Work Screen button
to return to the Main Work screen.
1.
2.
3.
4.
TABLE D:
Material Setup
Default Value/
Value to Enter
Split Air Regulation
Instructions/De nitions
Type Split Air Reg Desired type of application control channel being used for a speci c mate-
rial. CREATE MATERIAL NAME AS “AIR”.
Units In H
2
0
Oz in
2
Automatically changes with the type of material application selected.
Changes units for target application.
Preset Method Disabled User-de ned target rates can be con gured and when enabled can be ad-
justed from the Main Work screen using the Increment/Decrement buttons.
Target Rate 2.00 Establishes the desired rate of application in inches of H
2
0.
Max Rate 5.00 Maximum application rate in inches of H
2
0.
Min Rate 1.00 Minimum application rate in inches of H
2
0.
Inc/Dec % 5% Percentage of change of the entered target rate applied each time the
Increment/Decrement button is pressed on the Main Work screen.
STEP 8: Row Monitor Setup
At the Main Work screen, press the Row Monitor button .
Enter desired values using Table F as reference.
Press the Work Screen button
to return to the Main Work screen.
1.
2.
3.
TABLE F:
Row Monitor
Setup
Default Value/
Value to Enter Instructions/De nitions
Material Name See Instructions Material Name only appears on the Row Monitor Setup screen when all
control channels are disabled and material is set for Monitor Only. This is
only used for ground drive/nonhydraulic applications to monitor population
with high and low alarms. A material must be con gured and selected to
activate alarms.
High Alarm Delay 5 Desired number of seconds that high population can be above high alarm
point before alarm will sound.
Low Alarm Delay 5 Desired number of seconds that low population can be below low alarm
point before alarm will sound.
Population Adjust 100 Enter a % to allow for seed sensor population inaccuracies to achieve the
desired population display. 100% represents true calculation.
Population Filter 50 Set lter value to stabilize the monitored population display. Number can
be set to 0% for no ltering and 99% for high level ltering.
Row Fail Rate 2/1 (2 seeds
every 1 second)
Set to desired number of seeds per second to trigger seed sensor failure
alarm.
3
Vue de la page 2
1 2 3 4 5 6

Commentaires sur ces manuels

Pas de commentaire