Quick Setup Guide for IntelliAg Model YP30 30”
11001-1545-201002
©2010 DICKEY-john Corporation
Speci cations subject to change without notice.
STEP 1: Pre-Programming Preparation:
Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings.
If errors are detected (e.g., failed sensors, incorrect con guration) an alarm and code displays. Alarms are silenced by pressing the Alarm Cancel button . Refer to Operator’s
manual for troubleshooting assistance.
The system has three user levels. The system loads in User Level 1 (operator level) at every power cycle. Access to User Level 2 and 3 screens to setup constants (system con gura-
tion) requires a password.
1.
2.
3.
The Quick Setup Guide assumes the Virtual Terminal, Master Switch, Working Set Master Module,
Working Set Member Module, and all sensors have been connected and properly installed. Refer-
ence Operator’s manual for installation instructions. NOTE: The master switch is only required for
hydraulic control systems. Reference the manual for instructions to assign a master switch
as an auxiliary input.
STEP 3: Auto Con guration (Identi es sensors connected to each module)
Auto con g is performed at the factory, but may need to be done in the eld as changes
are made to the system or if options are added to the base planter.
Verify Auto Con g results are correct. Check that the correct number of rows are assigned
to the correct module and number of hopper sensors are assigned accurately.
To Run Auto Con g:
Press the Next Page button until the Module Con guration button appears.
Press the Module Con guration button .
Press the AUTO CONFIG button .
Hour glass will indicate system is being con gured detecting the presence of seed or hopper
sensors connected to each module and will be automatically assigned to the appropriate
module.
When Auto Con g completes, press the Row Assign button to display the Row
Assignment screen to verify correct Row # is assigned to the correct module based on serial
number.
Enter # of rows assigned to each module.
1.
1.
2.
3.
4.
5.
6.
STEP 5: Material Con guration Setup (Controlled Hydraulic Drive)
16 different materials can be con gured for use as planter controls. Reference the System
Con guration section in the Operator’s manual for additional information.
At the Main Menu screen, press the Control Setup button .
Select and press one of the Material buttons (Material 1-16).
Enter desired values from Table B.
Press the Control Setup button to return to the Control Setup screen.
Repeat steps 2-4 for additional materials.
Press the Channel Setup button to proceed to channel setup screen.
1.
2.
3.
4.
5.
6.
TABLE B:
Material Setup
Default Value/
Value to Enter
Controlled Hydraulic Drive
Instructions/De nitions
Matrl Label Matrl 1 Material Name can be customized to accurately de ne
the material’s type. Creating a name allows for quick
identi cation at the Control Setup screen.
Type Planter Control Desired type of application control channel being used
for a speci c material. The Material Type must correctly
match the Control Type to be able to select Material from
the Material Summary screen and operate properly.
Units Ks/Ac
S/Sec
Automatically changes with the type of material applica-
tion selected. Changes units for target application.
Preset Method Enable Enabled Preset Method allows 10 user-de ned target
rates to be adjusted from the Main Work screen using Inc
or Dec buttons. A Disabled Preset Method increases/de-
creases the target rate based on the % values set at the
Material Setup screen.
Seeds per Rev See Manual Set to number of seeds per 1 disc revolution.
Disc Low Limit
(Singulator Plus)
5 Set to desired min seed disc RPM.
Disc Low Limit
(Precision Finger)
40 Set to desired min seed disc RPM.
Disc High Limit
(Singulator Plus)
40 Set to desired max seed disc RPM.
Disc High Limit
(Precision Finger)
85 Set to desired max seed disc RPM.
High Pop Alarm 15% This is the percentage above the target population of
the planter channel if rows are assigned to the planter
channel. If rows are not assigned to a planter, this is
the percentage above average planter population for all
unassigned rows.
Low Pop Alarm 15% This is the percentage below the target population of the
planter channel if rows are assigned to the planter chan-
nel. If rows are not assigned to a planter channel, this is
the percentage below average planter population for all
unassigned rows.
Product Level
Alarm
Sets the level to trigger an alarm alerting of low product
levels. Entered value is an estimate in volume.
Row Fail Rate 2/1 (2 seeds
every 1 second)
Set to desired number of seeds per second to trigger
seed sensor failure alarm.
STEP 4: Row Status/Row Width Setup
At the Row Assignment screen, press the Row I/O button .
Begin entering desired values using Table A as reference.
Press the Work Screen button
when Row Status/Row Width con gurations are
complete to return to the Main Work screen.
1.
2.
3.
TABLE A: Row
Status/Row
Width Setup
Default Value
or Value to
Enter
Instructions/De nitions
Row Width 30” Enter row width distance in inches to calculate seed rate
correctly. NOTE: Using 15” planter in 30” mode should
change On/Off Pattern to Every 2nd Row Off.
Auto Update Width Enabled When enabled, implement width will automatically calcu-
late. If disabled, manually enter implement width.
On/Off Pattern Every Row On On/Off Pattern indicates speci c row patterns to be on
or off. Select pre-de ned planter All Row On pattern.
For other pre-de ned planter patterns or individual row
settings, reference Operator’s manual.
Pop/Block Pattern Every Row
Population
Determines which sensors are used to calculate popula-
tion and those used only for blockage detection. Select
pre-de ned Every Row Population. For other pre-de ned
patterns, reference Operator’s manual.
1
STEP 2: Change User Level to Dealer Level
To change the user level, a 6-digit password is required. Password includes the ve-digit
serial number found on the label of the Working Set Master or Information screen.
On the IntelliAg Main Work screen, press the Diagnostics button .
At the Diagnostics screen, press the Information button .
At the Information screen, record serial number of WSMT.
Press the Password button .
On the Password screen, enter the 6 digit password as follows: enter the rst digit as 2 for
User Level 2. For the next ve digits, enter the Working Set Master serial number taken
from the WSMT or Information screen.
Press the OK button . “Dealer screens on” appears at the bottom of screen con rm-
ing the password and dealer screens are activated.
Press the Work Screen button to return to the Main Work screen.
1.
2.
3.
4.
5.
6.
7.
SERIAL
NUMBER
1
MODULE
TYPE
MODULE
ADDR.
WSMB-POM
WSMB-POM
2
WSMB-18R
3
10001
10001
10002
WSMT-GY
10001
4
# OF
ROWS
MODULE
ADDR.
TYPE
ROW
#’s
5-8
1
WSMB-18R
2
WSMT- GY
4
1- 4
3
WSMB-18R
9-12
Module Configuration Screen Seed Sensor Configuration Screen
10002
10003
10001
WSMB-18R
WSMB-POM
WSMB-CFM
5
6
7
(Optional)
(Optional)
4
4
Vue de la page 0
1 2 3 4 5

Résumé du contenu

Page 1 - WSMT- GY

Quick Setup Guide for IntelliAg Model YP30 30” 11001-1545-201002 ©2010 DICKEY-john Corporation Specifi cations subject to change without notice. STEP

Page 2 - STEP 7: Row Monitor Setup

Quick Setup Guide for IntelliAg Model YP30 30” 11001-1545-201002 ©2010 DICKEY-john Corporation Specifi cations subject to change without notice.TABLE C

Page 3 - # of Clutches

Quick Setup Guide for IntelliAg Model YP30 30” 11001-1545-201002 ©2010 DICKEY-john Corporation Specifi cations subject to change without notice.TABLE

Page 4 - STEP 13: Summary Screen

Quick Setup Guide for IntelliAg Model YP30 30” 11001-1545-201002 ©2010 DICKEY-john Corporation Specifi cations subject to change without notice.STEP 12

Page 5 - System Component Installation

Quick Setup Guide for IntelliAg Model YP30 30” 11001-1545-201002 ©2010 DICKEY-john Corporation Specifi cations subject to change without notice.System

Commentaires sur ces manuels

Pas de commentaire