Quick Setup Guide for IntelliAg Model YP24 15” Air Pro
11001-1519-200908
©2009 DICKEY-john Corporation
Speci cations subject to change without notice.
STEP 1: Pre-Programming Preparation:
Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings.
If errors are detected (e.g., failed sensors, incorrect con guration) an alarm and code displays. Alarms are silenced by pressing the Alarm Cancel button
. Refer to Operator’s
manual for troubleshooting assistance.
The system has three user levels. The system loads in User Level 1 (operator level) at every power cycle. Access to User Level 2 and 3 screens to setup constants (system con gura-
tion) requires a password.
1.
2.
3.
The Quick Setup Guide assumes the Virtual Terminal, Master Switch, Working Set Master Module, Working
Set Member Module, and all sensors have been connected and properly installed. Reference Operator’s
manual for installation instructions. NOTE: The master switch is only required for hydraulic control
systems. Reference the manual for instructions to assign a master switch as an auxiliary input.
STEP 3: Auto Con guration (Identi es sensors connected to each module)
Auto con g is performed at the factory, but may need to be done in the eld as changes are
made to the system or if options are added to the base planter.
Verify Auto Con g results are correct. Check that the correct number of rows are assigned to the
correct module and number of hopper sensors are assigned accurately.
To Run Auto Con g:
Press the Next Page button until the Module Con guration button appears.
Press the Module Con guration button .
Press the AUTO CONFIG button .
Hour glass will indicate system is being con gured detecting the presence of seed or hopper
sensors connected to each module and will be automatically assigned to the appropriate
module.
When Auto Con g completes, press the Row Assign button to display the Row Assign-
ment screen to verify correct Row # is assigned to the correct module based on serial number.
Enter # of rows assigned to each module.
1.
1.
2.
3.
4.
5.
6.
STEP 4: Row Status/Row Width Setup
At the Row Assignment screen, press the Row I/O button .
Begin entering desired values using Table A as reference.
Press the Work Screen button when Row Status/Row Width con gurations are
complete to return to the Main Work screen.
1.
2.
3.
TABLE A: Row
Status/Row
Width Setup
Default Value
or Value to
Enter
Instructions/De nitions
Row Width 15” Enter row width distance in inches to calculate seed
rate correctly. NOTE: Using 15” planter in 30” mode
should change On/Off Pattern to Every 2nd Row Off.
Auto Update Width Enabled When enabled, implement width will automatically cal-
culate. If disabled, manually enter implement width.
On/Off Pattern Every Row On On/Off Pattern indicates speci c row patterns to
be on or off. Select pre-de ned planter All Row On
pattern. For other pre-de ned planter patterns or
individual row settings, reference Operator’s manual.
Pop/Block Pattern Every Row
Population
Determines which sensors are used to calculate
population and those used only for blockage detec-
tion. Select pre-de ned Every Row Population. For
other pre-de ned patterns, reference Operator’s
manual.
1
STEP 2: Change User Level to Dealer Level
To change the user level, a 6-digit password is required. Password includes the ve-digit
serial number found on the label of the Working Set Master or Information screen.
On the IntelliAg Main Work screen, press the Diagnostics button .
At the Diagnostics screen, press the Information button .
At the Information screen, record serial number of WSMT.
Press the Password button .
On the Password screen, enter the 6 digit password as follows: enter the rst digit as 2 for User
Level 2. For the next ve digits, enter the Working Set Master serial number taken from the
WSMT or Information screen.
Press the OK button . “Dealer screens on” appears at the bottom of screen con rming
the password and dealer screens are activated.
Press the Work Screen button to return to the Main Work screen.
1.
2.
3.
4.
5.
6.
7.
STEP 5A: Material Con guration Setup (Controlled Hydraulic Drive)
15 different materials can be con gured for use as planter controls. Reference the System Con-
guration section in the Operator’s manual for additional information.
At the Main Menu screen, press the Control Setup button .
Select and press one of the Material buttons (Material 1-15).
Enter desired values from Table B1.
Press the Control Setup button to return to the Control Setup screen.
Repeat steps 2-4 for additional materials.
Press the Channel Setup button to proceed to channel setup screen.
1.
2.
3.
4.
5.
6.
TABLE B1:
Material Setup
Default Value/
Value to Enter
Controlled Hydraulic Drive
Instructions/De nitions
Matrl Label Matrl 1 Material Name can be customized to accurately
de ne the material’s type. Creating a name allows for
quick identi cation at the Control Setup screen.
Type Planter Control Desired type of application control channel being
used for a speci c material. The Material Type must
correctly match the Control Type to be able to select
Material from the Material Summary screen and
operate properly.
Units Ks/Ac
S/Sec
Automatically changes with the type of material appli-
cation selected. Changes units for target application.
Preset Method Enable Enabled Preset Method allows 10 user-de ned target
rates to be adjusted from the Main Work screen
using Inc or Dec buttons. A Disabled Preset Method
increases/decreases the target rate based on the %
values set at the Material Setup screen.
Seeds per Rev See Manual Set to number of seeds per 1 disc revolution.
Disc Low Limit
(Air Pro)
5 Set to desired min seed disc RPM.
Disc High Limit
(Air Pro)
37 Set to desired max seed disc RPM.
High Pop Alarm 15% This is the percentage above the target population of
the planter channel if rows are assigned to the planter
channel. If rows are not assigned to a planter, this is
the percentage above average planter population for
all unassigned rows.
Low Pop Alarm 15% This is the percentage below the target population
of the planter channel if rows are assigned to the
planter channel. If rows are not assigned to a planter
channel, this is the percentage below average planter
population for all unassigned rows.
Product Level
Alarm
Sets the level to trigger an alarm alerting of low prod-
uct levels. Entered value is an estimate in volume.
Row Fail Rate 2/1 (2 seeds
every 1 second)
Set to desired number of seeds per second to trigger
seed sensor failure alarm.
SERIAL
NUMBER
1
MODULE
TYPE
MODULE
ADDR.
WSMB-POM
WSMB-POM
2
WSMB-18R
3
10001
10001
10002
WSMT-GY
WSMB-Rows
WSMB-POM
WSMB-CFM
10001
10002
10003
10001
4
5
6
7
# OF
ROWS
MODULE
ADDR.
TYPE
ROW
#’s
19-29
1
WSMB-18R
2
WSMT-GY
11
18
1- 18
3
WSMB-Rows
18
30-47
Module Configuration Screen Seed Sensor Configuration Screen
(optional)
(optional)
Vue de la page 0
1 2 3 4 5

Résumé du contenu

Page 1 - WSMB-Rows

Quick Setup Guide for IntelliAg Model YP24 15” Air Pro 11001-1519-200908 ©2009 DICKEY-john Corporation Specifi cations subject to change without notic

Page 2

Quick Setup Guide for IntelliAg Model YP24 15” Air Pro 11001-1519-200908 ©2009 DICKEY-john Corporation Specifi cations subject to change without notic

Page 3 - (Split Air Regulation)

Quick Setup Guide for IntelliAg Model YP24 15” Air Pro 11001-1519-200908 ©2009 DICKEY-john Corporation Specifi cations subject to change without notic

Page 4 - # of Clutches

Quick Setup Guide for IntelliAg Model YP24 15” Air Pro 11001-1519-200908 ©2009 DICKEY-john Corporation Specifi cations subject to change without notic

Page 5 - 467980160

Quick Setup Guide for IntelliAg Model YP24 15” Air Pro 11001-1519-200908 ©2009 DICKEY-john Corporation Specifi cations subject to change without notic

Commentaires sur ces manuels

Pas de commentaire